Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Air-conditioning
Audiometer testing system
Clean system for ventilation
Clean ventilation system
Clean ventilation systems
Clear out ventilation system
Dynamic visual acuity testing system
Functional test system
HVAC systems
I-c dynamic test system
Mechanical ventilation
Online test system
Systems
Systems for ventilation
Test system accessibility for users with special needs
Ventilation systems
Ventilator test system

Vertaling van "Ventilator test system " (Engels → Nederlands) :

TERMINOLOGIE
Ventilator test system

testsysteem voor beademingsapparaat


Dynamic visual acuity testing system

systeem voor dynamisch onderzoek van gezichtsscherpte




test system accessibility for users with special needs

systemen testen voor gebruikers met speciale behoeften | testen of interfaces kunnen worden gebruikt door mensen met een beperking | software-interface testen | systeemtoegankelijkheid voor gebruikers met speciale behoeften testen


i-c dynamic test system

dynamisch test inrichting voor geintegreerde schakelingen






clean system for ventilation | clear out ventilation system | clean ventilation system | clean ventilation systems

ventilatiesystemen reinigen


HVAC systems | mechanical ventilation | systems for ventilation | ventilation systems

ventilatiesystemen


Allergic alveolitis due to fungi, thermophilic actinomycetes and other organisms growing in ventilation [air-conditioning] systems

allergische alveolitis door schimmels, thermofiele actinomyceten en andere organismen die in ventilatie- [airconditioning-] systemen groeien
IN-CONTEXT TRANSLATIONS
Where an artificial ventilation system is used, an alarm system (tested regularly) and a ventilation back-up system must be installed.

Bij gebruik van kunstmatige ventilatie moet voor een alarmsysteem (dat regelmatig wordt getest) en een ventilatienoodvoorziening worden gezorgd.


8. The manufacturer shall ensure that for the Type 3 test set out in Annex V, the engine’s ventilation system does not permit the emission of any crankcase gases into the atmosphere.

8. Voor de in bijlage V beschreven test van type 3 zorgt de fabrikant ervoor dat het ventilatiesysteem van de motor geen cartergassen in de atmosfeer laat ontsnappen.


Where an artificial ventilation system is used, an alarm system (tested regularly) and a ventilation back-up system must be installed.

Bij gebruik van kunstmatige ventilatie moet voor een alarmsysteem (dat regelmatig wordt getest) en een ventilatienoodvoorziening worden gezorgd.


26.2. Air-conditioning system tested in accordance with section 9 of ISO 14269-2:1997 (Tractors and self-propelled machines for agriculture and forestry — Operator enclosure environment — Part 2: Heating, ventilation and air-conditioning test method and performance) and test reports are included in the information document: yes/no/not applicable (4)

26.2. Het klimaatregelingssysteem is getest in overeenstemming met punt 9 van ISO 14269-2:1997 (Tractors and self-propelled machines for agriculture and forestry -- Operator enclosure environment -- Part 2: Heating, ventilation and air-conditioning test method and performance) en de testrapporten zijn vermeld in het inlichtingenformulier: ja/neen/niet van toepassing (4)


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
26.1. Heating system tested in accordance with section 8 of ISO 14269-2:1997 (Tractors and self-propelled machines for agriculture and forestry — Operator enclosure environment — Part 2: Heating, ventilation and air-conditioning test method and performance) and test reports are included in the information document: yes/no/not applicable (4)

26.1. Het verwarmingssysteem is getest in overeenstemming met punt 8 van ISO 14269-2:1997 (Tractors and self-propelled machines for agriculture and forestry -- Operator enclosure environment -- Part 2: Heating, ventilation and air-conditioning test method and performance) en de testrapporten zijn vermeld in het inlichtingenformulier: ja/neen/niet van toepassing (4)


Any artificial ventilation systems inside the test cell shall be switched off.

Als in de testruimte kunstmatige ventilatiesystemen aanwezig zijn, worden deze uitgeschakeld.


If fitted, the engine bonnet, roof, all doors, windows and vents, except the intakes and outlets of the heating and ventilation system, shall be closed; one or two windows may be opened from the beginning of the demisting test for a total vertical distance of 25 mm if the vehicle manufacturer so requests.

Als het voertuig daarmee is uitgerust, worden de motorkap, het dak, alle deuren, vensters en verluchtingsopeningen, behalve de in- en uitlaten van het verwarmings- en het ventilatiesysteem, gesloten; een of twee vensters mogen vanaf het begin van de ontwasemingstest over een totale verticale afstand van 25 mm worden geopend als de fabrikant van het voertuig daarom verzoekt.


8. The manufacturer shall ensure that for the Type 3 test set out in Annex V, the engine’s ventilation system does not permit the emission of any crankcase gases into the atmosphere.

8. Voor de in bijlage V beschreven test van type 3 zorgt de fabrikant ervoor dat het ventilatiesysteem van de motor geen cartergassen in de atmosfeer laat ontsnappen.




datacenter (1): www.wordscope.nl (v4.0.br)

'Ventilator test system' ->

Date index: 2022-10-19
w